National Instruments PXI-2527 300 V, 64-Channel Multiplexer Switch Module

PXI-2527 High-Voltage Multiplexer Switch Module

The PXI-2527 is a high-voltage PXI multiplexer switch module designed for automated measurements, data acquisition and electronic test systems. It handles signals up to 300 V and provides configurable 1-wire, 2-wire and 4-wire multiplexer topologies.

With up to 64 input channels, electromechanical latching relays and hardware-triggered scanning, the PXI-2527 is well suited for expanding the measurement capacity of compatible PXI digital multimeters and other measurement instruments.

Key Features of the PXI-2527

  • 64-channel high-voltage multiplexer
  • Maximum switching voltage of 300 V
  • Maximum switching current of 2 A
  • 64×1 one-wire multiplexer configuration
  • 32×1 two-wire multiplexer configuration
  • 16×1 four-wire multiplexer configuration
  • Up to 140 relay cycles per second
  • 30 MHz maximum bandwidth
  • Electromechanical latching relays
  • Onboard relay-count tracking
  • Deterministic hardware triggering
  • Single-slot 3U PXI module

PXI-2527 Technical Specifications

Product ModelPXI-2527
Part Number778572-27
Product TypeHigh-Voltage Multiplexer Switch Module
Bus TypePXI Hybrid
Maximum Channel Count64 channels
Multiplexer Topologies64×1 one-wire, 32×1 two-wire or 16×1 four-wire
Maximum Switching Voltage300 V
Maximum Switching Current2 A
Maximum Bandwidth30 MHz
Maximum Scan Rate140 cycles/s
Relay TypeElectromechanical latching
Front Connector100-position HDI male
PXI Slots Required1
Operating Temperature0°C to 55°C
Dimensions21.6 × 2.0 × 13.0 cm
WeightApproximately 209 g

PXI-2527 Part Number and Configuration

ModelPart NumberConfiguration
PXI-2527778572-2764-channel, 300 V, 2 A PXI multiplexer
TB-2627779358-01Direct-mount screw-terminal block

Configurable Multiplexer Topologies

The PXI-2527 can be configured for three different multiplexer topologies, allowing one module to support several measurement requirements:

  • 64×1 one-wire: Provides the highest channel density for measurements that use a shared return path.
  • 32×1 two-wire: Routes differential or signal-and-return channel pairs to a common measurement instrument.
  • 16×1 four-wire: Supports four-wire resistance measurements where lead resistance must be compensated.

The appropriate topology should be selected according to the signal type, measurement method and wiring requirements of the test system.

High-Voltage Signal Switching

The PXI-2527 supports signals up to 300 V, making it suitable for medium- and high-voltage automated test applications. Its 2 A switching capability also allows the module to route a broad range of measurement and stimulus signals.

The voltage, current and switching-power limits are separate ratings and should not be treated as simultaneously available under every operating condition. System designers should verify the applicable derating curves and use the lowest rating among the module, terminal block, cable and connected instrument.

PXI Digital Multimeter Channel Expansion

The PXI-2527 can operate as a measurement front end for compatible NI PXI digital multimeters. It enables a single DMM to sequentially measure voltage, current, resistance, capacitance or inductance across multiple devices or test points.

This architecture reduces the number of measurement instruments required in high-channel-count systems while preserving software-controlled routing and repeatable test sequences.

Hardware-Triggered Scanning

Deterministic hardware triggers allow the PXI-2527 to coordinate relay operations with PXI instruments such as digital multimeters, digitizers and data acquisition modules. This capability supports faster automated scanning with less dependence on software timing.

The module also includes onboard relay counting. Test engineers can monitor relay usage and establish preventive-maintenance intervals based on actual switching activity.

Typical PXI-2527 Applications

  • Automated electronic production testing
  • High-channel-count voltage measurements
  • Two-wire and four-wire resistance measurements
  • Battery and power-system testing
  • Component characterization
  • Manufacturing process monitoring
  • Environmental and reliability testing
  • Data acquisition channel expansion
  • Research and laboratory measurement systems

Software and Driver Support

The PXI-2527 is controlled through the NI-SWITCH instrument driver. NI-SWITCH provides APIs for relay configuration, channel routing, scanning, triggering and relay-count monitoring.

The module can also be managed with NI Switch Executive, which provides graphical route configuration and simplifies the management of larger switching systems. Application development is supported in environments such as LabVIEW, LabWindows/CVI, C and compatible Microsoft development tools.

TB-2627 Terminal Block and Connectivity

The TB-2627 is the recommended screw-terminal block for the PXI-2527. It mounts directly to the module’s front connector and supports single or dual 1-wire, 2-wire and 4-wire multiplexer configurations.

Before operating the system, verify the terminal block configuration, conductor rating, insulation, strain relief and applicable safety requirements. The PXI-2527 is rated for Category I measurements and should not be connected directly to Category II, III or IV mains circuits.

PXI Chassis Integration

The PXI-2527 occupies one slot in a compatible 3U PXI or PXI Hybrid chassis. Chassis cooling, slot compatibility and operating-temperature limits should be confirmed before installation.

The module supports operation from 0°C to 55°C in most compatible chassis. When installed in certain older PXI-1000B or PXI-101x chassis, the maximum supported ambient temperature is reduced to 45°C.

PXI-2527 Troubleshooting

The module is not detected by the system

Confirm that the module is fully seated in a compatible PXI or PXI Hybrid slot. Check that the chassis and controller are operating correctly, then verify the module status in NI Measurement & Automation Explorer.

Channels do not route as expected

Verify that the selected NI-SWITCH topology matches the physical wiring. A 64×1 one-wire configuration uses different channel relationships from the 32×1 two-wire and 16×1 four-wire configurations.

Measurements are unstable or inaccurate

Check the terminal connections, cable insulation, shielding and grounding. For low-resistance measurements, use the four-wire topology to reduce errors caused by test-lead resistance.

Relay operations are slower than expected

Review the scan list, trigger configuration and connected instrument timing. Hardware-triggered scanning can provide more consistent operation than software-timed channel changes.

A relay channel may be worn

Read the onboard relay count and compare it with the expected service life under the actual switching load. Relay life depends on voltage, current, switching power and signal type.

PXI-2527 Compared with Related Multiplexer Modules

ModelChannel ConfigurationMaximum VoltageBest Suited For
PXI-252764×1 one-wire, 32×1 two-wire or 16×1 four-wire300 VHigh-voltage multipoint measurements
PXIe-252764×1 one-wire, 32×1 two-wire or 16×1 four-wire300 VNative PXI Express systems
PXI-2575196×1 one-wire or 98×1 two-wire100 VHigher channel-density signal routing
PXI-2576Configurable multi-bank multiplexer150 VFlexible multi-bank test systems

Recommended Related Products

Additional PXI switching, measurement and control products are available in the NI PXI Modules category.

Selecting the PXI-2527

Choose the PXI-2527 when an application requires up to 300 V signal handling, flexible one-wire through four-wire switching and integration with an existing PXI or PXI Hybrid system. It is particularly useful for expanding a DMM across multiple high-voltage measurement points.

If the system requires native PXI Express connectivity, consider the PXIe-2527. For applications requiring substantially more channels at lower voltage, the PXI-2575 may be a better option.

Why Choose the PXI-2527?

  • Combines high-voltage switching with flexible channel configurations
  • Supports one-wire, two-wire and four-wire measurement methods
  • Expands compatible PXI DMMs across multiple test points
  • Provides deterministic hardware-triggered scanning
  • Tracks relay usage for preventive maintenance
  • Integrates with NI-SWITCH and NI Switch Executive

Frequently Asked Questions

What is the PXI-2527 used for?

The PXI-2527 routes multiple voltage, current, resistance and other measurement signals to a common instrument. It is commonly used as a multiplexer front end for PXI digital multimeters.

How many channels does the PXI-2527 provide?

It provides up to 64 channels in a one-wire configuration. It can also operate as a 32×1 two-wire or 16×1 four-wire multiplexer.

What is the maximum voltage of the PXI-2527?

The module supports switching voltages up to 300 V within its specified Category I operating limits.

What is the maximum switching current?

The PXI-2527 supports switching currents up to 2 A. The applicable voltage, current and power limits must be checked for the specific signal and configuration.

Which terminal block is used with the PXI-2527?

The NI TB-2627 screw-terminal block, part number 779358-01, is designed for direct connection to the PXI-2527.

What is the part number for the PXI-2527?

The standard NI part number for the PXI-2527 is 778572-27.

Request a Quote for the PXI-2527

Contact us for current availability, lead time and project pricing for the PXI-2527 High-Voltage Multiplexer Switch Module. We can also help identify compatible PXI digital multimeters, terminal blocks, chassis and related switching modules for your test system.

Part Number(s): 778572-27

规格

Scan Rate: 140 cycles/s
Mode (n-wire): 1-wire, 2-wire, 4-wire
Bus Connector: PXI Hybrid
Maximum Switching Current DC: 2 A
Maximum Switching Voltage DC: 300 V
Relay Type: Electromechanical
Switch Bandwidth: 30 MHz
Number of Channels: 16, 32, 64
Number of Banks: 1, 2

Brand

National Instruments

相关产品

最近浏览

常见问题解答

是的。我们可以通过可靠的供应渠道提供全新原装产品。根据库存情况和客户需求,部分型号也可能提供二手或翻新产品。询价时请确认您所需的产品状况。

请告知我们所需的型号、数量和应用需求。我们将根据您的采购需求提供具有竞争力的报价和项目定价方案。

库存情况会定期变动。部分型号可立即发货,而其他型号则需要工厂订购或采购。请联系我们并提供确切的型号和零件编号,以了解最新的库存情况。

是的,我们为不同国家和地区的客户提供全球运输解决方案。我们可以根据您的目的地和配送要求安排可靠的物流服务。

是的,我们的技术团队可以根据您的应用需求,帮助您验证规格、系统兼容性、配件和产品选择。