PXI-2594

  • 所示价格仅供参考,数据来源于官方制造商网站。
  • 有关项目定价、批量折扣和采购支持,请联系我们的销售团队。

$2,750.00

NI PXI-2594, 2.5 GHz, 50 Ω, 4x1 PXI RF Multiplexer Switch Module

请在浏览器中启用JavaScript来完成此表单。
Target price, estimated delivery time or remarks...
分类:
19 People watching this product now!

National Instruments PXI-2594 2.5 GHz 4×1 50 Ohm RF Multiplexer Switch

PXI-2594 2.5 GHz 4×1 RF Multiplexer

The NI PXI-2594 is a 2.5 GHz, 50 Ω, 4×1 RF multiplexer switch module for routing high-frequency signals in automated test equipment. It connects one of four SMA channel ports to a common SMA port using latching electromechanical relays.

The module provides low insertion loss, controlled impedance, good VSWR and high channel isolation. It is suitable for RF source selection, receiver input routing, antenna switching, communications testing and multi-DUT production systems.

Key Features of the PXI-2594

  • 4×1 unterminated RF multiplexer topology
  • DC to 2.5 GHz operating frequency
  • 50 Ω nominal characteristic impedance
  • Four channel ports and one common port
  • Five front-panel SMA jacks
  • 30 V maximum switching voltage
  • 0.5 A switching and carry current
  • 10 W maximum RF power
  • Less than 1.35 dB insertion loss to 2.5 GHz
  • Greater than 35 dB isolation to 2.5 GHz
  • Latching electromechanical relays
  • Onboard relay-count tracking
  • PXI trigger and NI-SWITCH support

PXI-2594 Technical Specifications

Product ModelPXI-2594
Part Number778572-94
Product TypePXI RF Multiplexer Switch
Topology4×1 unterminated multiplexer
Frequency RangeDC to 2.5 GHz
Characteristic Impedance50 Ω nominal
Maximum Switching Voltage30 V
Maximum Switching Current0.5 A
Maximum Carry Current0.5 A
Maximum RF Power10 W
Insertion Loss to 1 GHzLess than 0.60 dB
Insertion Loss to 2 GHzLess than 1.10 dB
Insertion Loss to 2.5 GHzLess than 1.35 dB
Isolation to 1 GHzGreater than 55 dB
Isolation to 2 GHzGreater than 45 dB
Isolation to 2.5 GHzGreater than 35 dB
Typical Channel-to-Channel SkewLess than 1 ps
Typical Propagation DelayLess than 700 ps
Typical Rise TimeLess than 74 ps
Relay Operate Time10.4 ms
Listed Scan Rate45 cycles/s
Relay TypeElectromechanical, latching
Expected Mechanical Life1 × 10⁶ cycles
I/O ConnectorsFive SMA jacks
Bus ConnectionPXI hybrid
Operating Temperature0°C to 55°C
Module Format3U, one-slot PXI/cPCI module
Weight197 g

4×1 RF Multiplexer Architecture

The PXI-2594 routes one of four channel inputs to a single common connection. It can be used in either direction, allowing one source to address several DUT paths or allowing several sources to share one instrument input.

Only routes permitted by the 4×1 topology should be closed. Software should disconnect the existing channel before selecting another path when the connected sources could conflict.

2.5 GHz RF Performance

The module maintains less than 1.35 dB insertion loss through 2.5 GHz. Its insertion loss is lower at lower frequencies, measuring less than 0.60 dB through 1 GHz.

Isolation is greater than 55 dB through 1 GHz, greater than 45 dB through 2 GHz and greater than 35 dB through 2.5 GHz.

Low Skew and Fast Signal Response

Typical channel-to-channel skew is less than 1 ps, typical propagation delay is below 700 ps and typical rise time is below 74 ps.

These characteristics help preserve timing relationships when routing high-speed pulses and broadband RF signals.

10 W RF Power Handling

The PXI-2594 can carry as much as 10 W of RF power while remaining within the simultaneous voltage and current limits. Higher-power sources should be disabled or reduced before switching.

During relay movement, the signal path is temporarily unterminated. Some RF generators or amplifiers can be damaged by high reflected power if their outputs are not properly protected.

Unterminated Signal Paths

Unlike the PXI-2545, the PXI-2594 does not internally terminate unused channels. External 50 Ω terminations can be installed when inactive sources or DUT paths require a defined load.

This unterminated architecture avoids the lower power limitations associated with internal terminations but requires the system designer to manage unused RF ports.

Relay-Count Tracking

Onboard relay-count tracking records switching activity. Maintenance personnel can use the count to identify heavily used channels and plan relay service before a failure interrupts production.

Electrical life depends strongly on RF power, DC voltage, current, switching frequency and whether active signals are switched.

Typical PXI-2594 Applications

  • RF signal-generator routing
  • Spectrum-analyzer input selection
  • RF receiver testing
  • Antenna-path switching
  • Communications equipment validation
  • RF component characterization
  • Multi-DUT production testing
  • Automated test equipment
  • High-speed pulse routing

NI-SWITCH Software Support

NI-SWITCH provides software functions for connecting a channel to the common, disconnecting routes, configuring scan lists, selecting PXI trigger sources and reading relay counts.

NI Switch Executive can combine the PXI-2594 with other switch modules and define logical route names for use in LabVIEW or TestStand sequences.

PXI Hardware Triggering

The module accepts input triggers from PXI trigger lines 0 through 7. The minimum specified trigger pulse width is 150 ns with the standard digital-filter configuration.

Output triggers can be sent to the PXI trigger bus to coordinate route completion with RF generators, analyzers or digitizers.

PXI-2594 Troubleshooting

The module is not detected in NI MAX

Confirm that the PXI-2594 is fully installed in a compatible PXI or hybrid slot. Check chassis power, controller communication and NI-SWITCH installation.

No signal appears at the common port

Verify the selected channel and route. Inspect SMA cables and confirm that another route has not been left in an incompatible state.

Insertion loss is higher than expected

Inspect SMA connector condition, cable loss, adapter loss and the calibration reference plane. Compare measurements with the correct frequency-dependent limit.

An inactive source shows unexpected reflections

The PXI-2594 is unterminated. Install a suitable external 50 Ω termination if the source requires a defined load while disconnected.

The relay does not switch reliably

Check the relay count and test the path without active RF power. Confirm that the connected voltage, current and power have remained within specification.

PXI-2594 vs PXI-2545

FeaturePXI-2594PXI-2545
TopologyUnterminated 4×1Terminated 4×1
Maximum Frequency2.5 GHz2.7 GHz
Insertion LossLess than 1.35 dB to 2.5 GHzLess than 2 dB to 2.7 GHz
Internal 50 Ω TerminationsNoYes
Best Suited ForLow-loss, unterminated signal routingApplications requiring terminated inactive channels

PXI-2594 vs PXI-2595

The PXI-2594 provides a 4×1 topology and operates to 2.5 GHz. The PXI-2595 provides higher-frequency switching up to 5 GHz but uses a different topology and performance envelope.

Choose the PXI-2594 when four-channel routing, low insertion loss and 2.5 GHz coverage meet the application requirements.

Recommended Related Products

Frequently Asked Questions

What is the PXI-2594 part number?

The standard NI ordering part number is 778572-94.

What is the PXI-2594 topology?

It is a four-channel-to-one-common, or 4×1, RF multiplexer.

What is the maximum frequency?

The module is specified for RF signals from DC to 2.5 GHz.

Does it include internal termination?

No. The PXI-2594 is an unterminated multiplexer.

What is the maximum RF power?

The maximum RF power is 10 W, subject to the 30 V and 0.5 A limits.

Does the PXI-2594 use latching relays?

Yes. It uses latching electromechanical relays.

Can relay usage be monitored?

Yes. The module supports onboard relay-count tracking.

Which software controls the PXI-2594?

The module is controlled with NI-SWITCH and can be integrated with NI Switch Executive.

Request a Quote for the PXI-2594

Contact us for current availability, lead time and project pricing for the PXI-2594 2.5 GHz 4×1 RF Multiplexer. We can also help select SMA cables, external terminations and related RF switch modules.

Part Number(s): 778572-94

规格

Bus Connector: PXI Hybrid
Maximum Switching Voltage AC: 30 V
Relay Type: Electromechanical
Switch Bandwidth: 2.5 GHz
Characteristic Impedence: 50 Ohm
Max Insertion Loss: -1.35 dB
Number of Channels: 4
Number of Banks: 1
Termination: No

Brand

National Instruments

相关产品

最近浏览

常见问题解答

是的。我们可以通过可靠的供应渠道提供全新原装产品。根据库存情况和客户需求,部分型号也可能提供二手或翻新产品。询价时请确认您所需的产品状况。

请告知我们所需的型号、数量和应用需求。我们将根据您的采购需求提供具有竞争力的报价和项目定价方案。

库存情况会定期变动。部分型号可立即发货,而其他型号则需要工厂订购或采购。请联系我们并提供确切的型号和零件编号,以了解最新的库存情况。

是的,我们为不同国家和地区的客户提供全球运输解决方案。我们可以根据您的目的地和配送要求安排可靠的物流服务。

是的,我们的技术团队可以根据您的应用需求,帮助您验证规格、系统兼容性、配件和产品选择。