National Instruments

PXI 系统

CompactDAQ 系统

CompactRIO 系统

PCI 模块

USB 设备

USRP软件无线电

National Instruments Test and Measurement Hardware

National Instruments (NI) provides modular hardware and software platforms for automated testing, data acquisition, sensor measurement, embedded control, RF research and industrial monitoring. NI products are widely used in engineering laboratories, validation systems, production test stations, research facilities and long-term monitoring installations.

PXISOURCE supplies NI PXI and PXIe systems, CompactDAQ hardware, CompactRIO controllers and chassis, C Series I/O modules, PCI and PCIe boards, USB measurement devices and USRP software-defined radios. Selecting the correct platform requires matching the application, signal type, channel count, bandwidth, timing, processing, environmental and software requirements.

National Instruments Product Categories

Product Family
Unique Category
Core Architecture
Best Fit

PXI Systems
Modular Automated Test Platform
PXI or PXI Express chassis with an embedded or remote controller and modular instruments
High-performance automated test, electronic validation, semiconductor test, RF and synchronized measurement

CompactDAQ Systems
Modular Sensor Data Acquisition
USB, Ethernet or controller-based chassis using interchangeable C Series I/O modules
Benchtop, portable, distributed and mixed-sensor data acquisition

CompactRIO Systems
Real-Time FPGA Control Platform
Real-time processor, user-programmable FPGA and modular industrial I/O
Deterministic control, embedded monitoring, hardware-in-the-loop and industrial systems

C Series Modules
Conditioned Modular I/O
Compact I/O modules with signal conversion, conditioning, isolation and sensor connectivity
Voltage, current, temperature, strain, vibration, digital I/O, relay and communication applications

PCI and PCIe Modules
Internal Computer-Based Measurement
Measurement, control and communication boards installed directly in a compatible desktop or industrial computer
Fixed test stations requiring direct PC integration and low-latency bus access

USB Devices
External Computer-Based Measurement
Portable measurement and communication hardware connected directly to a host computer through USB
Laboratory development, education, troubleshooting and compact automated systems

USRP Software Defined Radio Devices
Software-Defined RF Platform
RF transceiver hardware with host- or FPGA-based signal processing
Wireless research, spectrum monitoring, communications prototyping, radar and signal intelligence

How the NI Hardware Platforms Differ

The best NI platform is determined by the complete system requirement rather than a single specification. PXI emphasizes modular instrumentation and synchronization, CompactDAQ emphasizes flexible sensor measurement, CompactRIO adds deterministic real-time processing and FPGA control, while PCI, USB and USRP products address specific computer-based or RF applications.

Application Requirement
Recommended Platform
Selection Reason

High-performance automated test using multiple instrument types
PXI or PXI Express
Provides a shared chassis, high-throughput backplane, timing resources and modular instruments

Portable or distributed sensor measurement
CompactDAQ
Supports interchangeable signal-conditioned modules with USB or Ethernet connectivity

Deterministic machine control or FPGA-based processing
CompactRIO
Combines a real-time processor, FPGA and industrial I/O in an embedded architecture

Measurement hardware installed inside a desktop computer
PCI or PCIe
Provides direct internal bus integration without a separate external chassis

Compact connection to a laptop or laboratory computer
USB
Provides straightforward external connectivity and portable deployment

Wireless algorithm development and RF prototyping
USRP
Provides a software-defined RF architecture with configurable signal-processing workflows

NI PXI and PXI Express Systems

PXI is a modular test and measurement platform designed for applications that require multiple synchronized instruments, automated operation and scalable channel counts. A complete PXI system normally consists of a chassis, controller, measurement modules, instrument drivers and test software.

The PXI chassis provides power, cooling, backplane communication, reference clocks and trigger resources. The PXI controller runs the operating system, drivers and test application. The installed PXI modules perform acquisition, generation, switching, measurement, communication or control functions.

PXI Express uses PCI Express backplane technology and is generally preferred for high-speed digitizers, RF instruments, FPGA modules, digital pattern instruments and continuous data streaming. Conventional PXI remains important for maintaining validated legacy systems using PCI-based modules.

Common PXI Instrument Functions

Multifunction data acquisition and analog output
Oscilloscopes and high-speed digitizers
RF signal generation, analysis and vector signal transceiver functions
Digital multimeters and LCR measurement
Source measure units and programmable power supplies
Matrix, multiplexer and RF switching
Semiconductor digital pattern testing
FPGA processing and FlexRIO instrumentation
Sensor, sound, vibration and bridge measurement
Industrial, automotive and instrument communication interfaces

NI CompactDAQ Systems

CompactDAQ is a modular data acquisition platform for measuring electrical and physical signals. A typical system combines a CompactDAQ chassis with one or more C Series modules selected for the connected sensors.

CompactDAQ chassis are available with different communication interfaces, slot counts and controller architectures. USB chassis are well suited to local benchtop measurement, while Ethernet chassis support longer distances and distributed acquisition. Controller-based CompactDAQ systems can perform measurement and logging without depending on a continuously connected external computer.

CompactDAQ is commonly selected for temperature, voltage, current, strain, pressure, force, sound, vibration and digital measurements. Module-level signal conditioning can reduce the need for separate external conditioners, but the sensor interface and accessory requirements must still be verified.

NI CompactRIO Systems

CompactRIO combines a real-time processor, user-programmable FPGA and modular I/O for embedded measurement and control. The real-time processor executes application logic and communication tasks, while the FPGA can handle operations requiring precise timing, high-speed logic or deterministic response.

CompactRIO is appropriate when the system must continue operating independently of a Windows computer or must respond to input signals within defined timing limits. Common applications include machine control, condition monitoring, energy systems, mobile equipment, hardware-in-the-loop testing and long-duration field installations.

CompactRIO selection should consider processor performance, FPGA resources, C Series slot count, networking, storage, operating temperature, power input, software licensing and required industrial interfaces.

NI C Series I/O Modules

C Series modules provide the measurement and control interfaces used by CompactDAQ and CompactRIO systems. Depending on the model, a module may include analog-to-digital or digital-to-analog conversion, isolation, filtering, excitation, bridge completion, sensor power, industrial communication or relay circuitry.

C Series Function
Typical Signals
Important Selection Factors

Analog Input
Voltage and current
Input range, resolution, sampling architecture, isolation and channel count

Analog Output
Voltage and current generation
Output range, update rate, drive capability, isolation and startup state

Temperature
Thermocouple and RTD sensors
Sensor type, cold-junction compensation, wire configuration and accuracy

Dynamic Signal
IEPE, sound and vibration sensors
Sample rate, simultaneous sampling, excitation, coupling and dynamic range

Bridge Measurement
Strain, load, force, pressure and torque sensors
Bridge type, excitation, completion, mV/V range and remote sensing

Digital I/O
Logic, industrial digital signals and pulse control
Logic level, sourcing or sinking, isolation, current and update timing

Relay Output
Electromechanical switching
Topology, voltage, current, switching power and expected relay life

Communication
CAN, LIN, serial and industrial buses
Protocol, port count, transceiver type, isolation and software support

C Series module compatibility depends on both the module and the selected CompactDAQ or CompactRIO chassis. Some functions, timing modes and software APIs are platform-specific. Verify the module manual, chassis documentation and driver support before ordering.

NI PCI, PCIe and USB Devices

NI PCI and PCIe products install directly in a compatible desktop or industrial computer. They are suitable for fixed systems where the computer provides the enclosure, processor, storage and user interface. Product families include multifunction DAQ, digital I/O, counters, high-speed digitizers, dynamic signal acquisition, FPGA hardware and communication interfaces.

Before selecting an internal board, confirm the computer’s physical slot, PCI or PCIe interface, lane configuration, available space, power capacity, operating system and driver version. Conventional PCI and PCI Express are not physically interchangeable.

NI USB devices provide external measurement, digital I/O, digitizer, multimeter, counter, FPGA, RF and communication functions. They are useful when portability, simple host connection or laptop compatibility is more important than the density and synchronization capabilities of a PXI system.

USB bandwidth is shared across the host controller and should be reviewed when several high-rate devices operate simultaneously. Cable length, power requirements, grounding and connector retention should also be considered for industrial installations.

NI and Ettus USRP Software Defined Radios

USRP software-defined radio devices provide configurable RF transmit and receive hardware for wireless research and development. Signal generation, acquisition, modulation, demodulation and analysis are implemented primarily through software or programmable FPGA resources.

USRP platforms support applications such as wireless communications research, spectrum monitoring, direction finding, radar development, channel sounding, signals intelligence, education and algorithm prototyping. Depending on the product family, software development may use the UHD driver, GNU Radio, Python, C++, MATLAB or supported NI software.

USRP selection requires the operating frequency range, instantaneous bandwidth, number of transmit and receive channels, phase-coherence requirements, FPGA resources, host interface, reference clock, synchronization method and intended software workflow.

How to Select National Instruments Hardware

1. Define the Application Architecture

Determine whether the system is intended for automated test, sensor measurement, embedded control, data logging, RF research or industrial communication. This first decision usually identifies the most suitable platform family.

2. Identify Every Signal and Sensor

Record the electrical interface for each channel, including voltage, current, thermocouple, RTD, bridge, IEPE, charge, digital logic, relay, counter, encoder or communication bus. The measured physical parameter alone does not identify the required hardware.

3. Calculate Channels, Rate and Bandwidth

Specify the active channel count, sample rate, measurement bandwidth, input range and required resolution. Also determine whether channels must be sampled simultaneously or whether multiplexed acquisition is acceptable.

4. Determine Timing and Synchronization Requirements

Applications involving phase, waveform correlation, stimulus-response testing or several instruments may require shared sample clocks, start triggers, reference clocks or timestamp synchronization. Installing devices in the same system does not automatically guarantee synchronized measurements.

5. Choose the Processing Architecture

A host-based system is appropriate when a Windows or Linux computer can manage acquisition and analysis. Select real-time or FPGA hardware when the application requires deterministic response, independent operation, custom high-speed logic or low-latency control.

6. Review Isolation and Grounding

Confirm channel-to-earth and channel-to-channel isolation requirements, common-mode voltage, grounding arrangements and cable shielding. Incorrect grounding can introduce noise, measurement error or unsafe voltage conditions.

7. Check Mechanical and Environmental Requirements

Review slot type, chassis capacity, cooling, power input, installation space, mounting, operating temperature, shock, vibration and connector access. A technically compatible module may still be unsuitable for the intended installation environment.

8. Verify Software and Driver Support

Confirm the operating system, driver, programming environment and application version before purchasing hardware. A legacy product may be electrically suitable but unsupported by the intended operating system or current driver release.

NI Software and Driver Ecosystem

NI hardware is supported by different software environments and instrument drivers. The correct software stack depends on the product family and application.

Software or Driver
Primary Function
Typical Hardware

LabVIEW
Graphical application development, measurement, analysis and control
PXI, CompactDAQ, CompactRIO, USB, PCI and supported USRP hardware

NI-DAQmx
Configuration and programming of compatible data acquisition hardware
CompactDAQ, supported C Series, PXI DAQ, PCIe DAQ and USB DAQ

TestStand
Automated test sequencing, execution, reporting and code-module management
PXI and other automated test systems

InstrumentStudio
Interactive configuration and measurement using supported modular instruments
Compatible PXI oscilloscopes, generators, SMUs, DMMs and RF instruments

FlexLogger
Configuration-based sensor measurement and data logging
Compatible CompactDAQ, PXI and C Series hardware

LabVIEW Real-Time and FPGA
Deterministic applications and user-programmable hardware logic
CompactRIO, sbRIO and supported FPGA-based PXI hardware

UHD
Open-source host driver and API for compatible USRP devices
NI and Ettus USRP software-defined radios

Driver support varies by model, hardware revision, operating system and software release. Confirm compatibility through the documentation for the exact part number rather than assuming that every product in a family uses the same driver.

System Compatibility and Accessories

A complete NI system may require more than the primary chassis or module. Confirm all necessary accessories during system planning:

Terminal blocks, connector blocks and breakout accessories
Shielded cables, sensor cables and bus-specific transceivers
Bridge-completion, cold-junction or sensor-conditioning accessories
Rack-mount, DIN-rail and strain-relief hardware
Power supplies and country-specific power cords
Synchronization, trigger and reference-clock cables
PXI filler panels and slot blockers for correct airflow
Software licenses, drivers and analysis toolkits
Calibration documentation and traceability requirements

Part numbers are important because one product model may have several connector, memory, channel, frequency, bandwidth or software configurations. Provide the complete NI part number whenever possible.

Typical Applications

Automated production and functional testing
Electronic design validation and verification
Semiconductor characterization and production test
Automotive, battery and electric-vehicle testing
Aerospace, defense and avionics validation
Temperature, strain, vibration and structural measurement
Industrial machine monitoring and control
Hardware-in-the-loop and real-time simulation
RF, radar and wireless communications research
Energy, power quality and renewable-energy testing
University teaching and scientific research
Long-duration data logging and condition monitoring

Legacy NI Hardware Replacement

Replacing a discontinued NI product requires more than selecting a newer model with similar channel counts. The replacement may use a different bus, connector, terminal block, sample clock, voltage range, isolation architecture, driver or software API.

Compare the following before approving a replacement:

Complete model and part number
PXI, PXIe, PCI, PCIe, USB or C Series form factor
Signal ranges, channel count and timing architecture
Connector type, cable and terminal-block pinout
Sampling rate, bandwidth and simultaneous or multiplexed operation
Isolation, common-mode and grounding specifications
Chassis, controller and slot compatibility
Operating-system and driver support
Application-code and configuration compatibility
Calibration and system-requalification requirements

A newer product may offer improved performance but still require wiring changes, software updates or complete system revalidation.

National Instruments Procurement and RFQ Guide

Provide the following information for accurate product identification and quotation:

Complete NI model and part number
Required quantity
Target application and measured signal types
Channel count, sample rate and bandwidth
Existing chassis, controller or host-computer model
Required terminal blocks, cables and accessories
Operating system and NI software or driver version
Calibration-document requirements
New or pre-owned hardware preference
Delivery destination and required delivery date

If the exact product number is unavailable, provide photographs of the model label, front connector and system configuration. This helps distinguish between hardware revisions and ordering options that may share a similar model name.

FAQ

What is National Instruments hardware used for?

NI hardware is used for automated testing, data acquisition, sensor measurement, embedded control, RF research, semiconductor test, industrial monitoring and scientific experimentation.

What is the difference between PXI and CompactDAQ?

PXI is a modular instrumentation platform for high-performance automated test and synchronized mixed-instrument systems. CompactDAQ focuses on flexible sensor and electrical measurement using portable or distributed chassis and C Series I/O modules.

What is the difference between CompactDAQ and CompactRIO?

CompactDAQ is primarily designed for data acquisition controlled by a host computer or integrated controller. CompactRIO adds a real-time processor and user-programmable FPGA for deterministic control, independent operation and custom high-speed logic.

Can the same C Series module work in CompactDAQ and CompactRIO?

Many C Series modules support both platforms, but compatibility, operating modes, timing and driver support can differ. Verify the exact module and chassis combination before ordering.

Can a conventional PXI module be installed in a PXIe chassis?

Only when the chassis provides a compatible hybrid slot and the module meets the connector and signaling requirements. A PXIe peripheral slot without hybrid support cannot accept a conventional PXI module.

Do all NI data acquisition products use NI-DAQmx?

No. Many DAQ devices use NI-DAQmx, while RF instruments, oscilloscopes, FPGA products, industrial interfaces and USRP devices may use different drivers. Check the software requirements for the exact product.

Is a model number sufficient for ordering NI hardware?

Not always. Some model families have several connector, memory, bandwidth or configuration options. The complete NI part number provides more reliable identification.

Related National Instruments Product Families

Choose PXI for synchronized modular instrumentation, CompactDAQ for flexible sensor acquisition, CompactRIO for real-time FPGA control, PCI or USB hardware for computer-based measurement, and USRP for software-defined RF development. Each platform should be selected as a complete system that includes compatible hardware, accessories, drivers and application software.

National Instruments Products from PXISOURCE

PXISOURCE supports engineers, system integrators, laboratories and procurement teams with NI product identification, platform selection, chassis and module compatibility review, accessory matching and legacy-system replacement. Send the required model numbers, part numbers, quantities and system configuration for a technically matched quotation.

Need help selecting the right NI solution? Email [email protected] or contact PXISOURCE on WhatsApp.